NTIS 바로가기한국방사선학회 논문지 = Journal of the Korean Society of Radiology, v.16 no.3, 2022년, pp.257 - 263
In intracavitary radiotherapy, it is essential to verify the correct location of radiation source among quality control items because an incorrect location will irradiate an unnecessary dose to normal tissues. As a basic study of digital line dosimeters, this study fabricated a unit cell dosimeter b...
S. Nag, "High Dose Rate Brachytherapy: Its Clinical Applications and Treatment Guidelines", Technology in cancer research & treatment, Vol. 3, No. 3, pp. 449-455, 2004. http://dx.doi.org/10.1177/153303460400300305
K. J. Lee, S. H. An, R. N. Lee, "Monte Carlo Evaluation for the Effect of Positional Inaccuracy of Source on Patient's Dose in High-Dose-Rate Brachytherapy", Journal of the Korean Physical Society, Vol. 55, No. 6, pp. 2361-2365, 2009. http://dx.doi.org/10.3938/jkps.55.2361
K. Yogo, A. Matsushita, Y. Tatsuno, T. Shimo, S. Hirota, M. Nozawa, S. Ozawa, H. Ishiyama, H. Yasuda, Y. Nagata, K. Hayakawa, "Imaging Cherenkov emission for quality assurance of high-dose-rate brachytherapy", Scientific reports, Vol. 10, No. 1, pp. 1-10, 2020. http://dx.doi.org/10.1038/s41598-020-60519-z
R. Nath, L. L. Anderson, J. A. Meli, A. J. Olch, J. A. Stitt, J. F. Williamson, "Code of practice for brachytherapy physics: report of the AAPM Radiation Therapy Committee Task Group No. 56. American Association of Physicists in Medicine", Medical Physics, Vol. 24, No. 10, pp. 1557-1598, 1997. https://doi.org/10.1118/1.597966
J. Venselaar, J. Perez-Calatayud, A practical guide to quality control of brachytherapy equipment, ESTRO booklet No. 8, Brussels: European Society for Therapeutic Radiology and Oncology, 2004.
M. D. C. Evans, S. Devic, E. B. Podgorsak, "High dose-rate brachytherapy source position quality assurance using radiochromic film", Medical Dosimetry, Vol. 32, No. 1, pp. 13-15, 2007. http://dx.doi.org/10.1016/j.meddos.2006.10.001
Z. Li, "Radiation damage effects in Si materials and detectors and rad-hard Si detectors for SLHC", Journal of Instrumentation, Vol. 4, No. 3, pp. 3011, 2009. http://dx.doi.org/10.1088/1748-0221/4/03/P03011
G. Hajdok, J. J. Battista, I. A. Cunningham, "Fundamental X-ray interaction limits in diagnostic imaging detectors: Spatial resolution", Medical Physics, Vol. 35, No. 7, pp. 3180-3193, 2008. http://dx.doi.org/10.1118/1.2924219
K. T. Kim, Y. J. Heo, M. J. Han, K. M. Oh, Y. K. Kim, S. W. Kim, S. K. Park, "Development and evaluation of multi-energy PbO dosimeter for quality assurance of image-guide radiation therapy devices", Journal of Instrumentation, Vol 12, No. 4, pp. 3024, 2017. http://dx.doi.org/10.1088/1748-0221/12/04/C04024
U. N. Roy, G. S. Camarda, Y. Cui, R. Gul, G. Yang, J. Zazvorka, V. Dedic, J. Franc, R. B. James, "Evaluation of CdZnTeSe as a high-quality gamma-ray spectroscopic material with better compositional homogeneity and reduced defects", Scientific reports, Vol. 9, No. 1, pp. 1-7, 2019. http://dx.doi.org/10.1038/s41598-019-43778-3
Y. C. Chang, R. B. James, "Electronic and optical properties of HgI2", PHYSICAL REVIEW B, Vol. 46, No. 23, pp. 15040-15045, 1992. https://dx.doi.org/10.1103/physrevb.46.15040
L. A. R. da Rosa, D. F. Regulla, U. A. Fill, "Reproducibility study of TLD-100 micro-cubes at radiotherapy dose level", Applied radiation and isotopes, Vol. 50, No. 3, pp. 573-557, 1999. https://doi.org/10.1016/s0969-8043(98)00068-2
F. M. Khan, J. P. Gibbons, Quality Assurance, Chapter 17 of, Khan's the physics of radiation therapy, 5th Ed., Lippincott Williams & Wilkins, pp. 371-404, 2014
International Commission on Radiation Units and measurements, Determination of absorbed dose in a patient irradiated by beams of X- or gamma-rays in radiotherapy procedures - approved 1976, report 24, Washington, 1977.
International Commission on Radiation Units and measurements, Prescribing, Recording, and Reporting Brachytherapy for Cancer of the Cervix, Report 89, England, 2013.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
Free Access. 출판사/학술단체 등이 허락한 무료 공개 사이트를 통해 자유로운 이용이 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.