NTIS 바로가기Electrophoresis, v.27 no.16, 2006년, pp.3284 - 3296
Kim, Sung-Jin (Biosensor Group, Electronics and Telecommunications Research Institute (ETRI), Daejeon, Korea) , Yang, Haesik (Biosensor Group, Electronics and Telecommunications Research Institute (ETRI), Daejeon, Korea) , Kim, Kyuwon (Biosensor Group, Electronics and Telecommunications Research Institute (ETRI), Daejeon, Korea) , Lim, Yong Taik (Biosensor Group, Electronics and Telecommunications Research Institute (ETRI), Daejeon, Korea) , Pyo, Hyeon-Bong (Biosensor Group, Electronics and Telecommunications Research Institute (ETRI), Daejeon, Korea)
For disposable microfluidic devices, easy and inexpensive fabrication is essential. Consequently, replication of microfluidic devices, using injection molding or hot embossing, from a master-mold is widely used. However, the conventional master-mold fabrication technique is unsatisfactory in terms o...
Burns, Mark A., Johnson, Brian N., Brahmasandra, Sundaresh N., Handique, Kalyan, Webster, James R., Krishnan, Madhavi, Sammarco, Timothy S., Man, Piu M., Jones, Darren, Heldsinger, Dylan, Mastrangelo, Carlos H., Burke, David T.. An Integrated Nanoliter DNA Analysis Device. Science, vol.282, no.5388, 484-487.
Wang, Y.-C., Stevens, A. L., Han, J.. Million-fold Preconcentration of Proteins and Peptides by Nanofluidic Filter. Analytical chemistry, vol.77, no.14, 4293-4299.
Li, Nianzhen, Hsu, Chia-Hsien, Folch, Albert. Parallel mixing of photolithographically defined nanoliter volumes using elastomeric microvalve arrays. Electrophoresis, vol.26, no.19, 3758-3764.
Kim, S.-J., Lim, Y. T., Yang, H., Shin, Y. B., Kim, K., Lee, D.-S., Park, S. H., Kim, Y. T.. Passive Microfluidic Control of Two Merging Streams by Capillarity and Relative Flow Resistance. Analytical chemistry, vol.77, no.19, 6494-6499.
Heckele, M, Schomburg, W K. Review on micro molding of thermoplastic polymers. Journal of micromechanics and microengineering.: structures, devices, and systems, vol.14, no.3, R1-R14.
10.1002/(SICI)1522-2683(20000101)21:1<12::AID-ELPS12>3.0.CO;2-7
10.1002/(SICI)1522-2683(20000101)21:1<27::AID-ELPS27>3.0.CO;2-C
Lee, L. James, Madou, Marc J., Koelling, Kurt W., Daunert, Sylvia, Lai, Siyi, Koh, Chee Guan, Juang, Yi-Je, Lu, Yumin, Yu, Liyong. Design and Fabrication of CD-Like Microfluidic Platforms for Diagnostics: Polymer-Based Microfabrication. Biomedical microdevices, vol.3, no.4, 339-351.
Musyimi, Harrison K., Guy, Jason, Narcisse, Damien A., Soper, Steven A., Murray, Kermit K.. Direct coupling of polymer-based microchip electrophoresis to online MALDI-MS using a rotating ball inlet. Electrophoresis, vol.26, no.24, 4703-4710.
Jensen, Martin F., McCormack, John E., Helbo, Bjarne, Christensen, Leif Højslet, Christensen, Thomas R., Geschke, Oliver. Rapid prototyping of polymer microsystems via excimer laser ablation of polymeric moulds. Lab on a chip, vol.4, no.4, 391-395.
Liao, Yunn-Shiuan, Chen, Shun-Tong, Lin, Chang-Sheng. Development of a high precision tabletop versatile CNC wire-EDM for making intricate micro parts. Journal of micromechanics and microengineering.: structures, devices, and systems, vol.15, no.2, 245-253.
Mela, Petra, van den Berg, Albert, Fintschenko, Yolanda, Cummings, Eric B., Simmons, Blake A., Kirby, Brian J.. The zeta potential of cyclo-olefin polymer microchannels and its effects on insulative (electrodeless) dielectrophoresis particle trapping devices. Electrophoresis, vol.26, no.9, 1792-1799.
Arnold, J., Dasbach, U., Ehrfeld, W., Hesch, K., Löwe, H.. Combination of excimer laser micromachining and replication processes suited for large scale production. Applied surface science, vol.86, no.1, 251-258.
Turner, Ryan, Desta, Yohannes, Kelly, Kevin, Zhang, Jian, Geiger, Emil, Cortez, Steve, Mancini, Derrick C. Tapered LIGA HARMs. Journal of micromechanics and microengineering.: structures, devices, and systems, vol.13, no.3, 367-372.
Hong, Chien-Chong, Choi, Jin-Woo, Ahn, Chong H.. A novel in-plane passive microfluidic mixer with modified Tesla structures. Lab on a chip, vol.4, no.2, 109-113.
Kukharenka, E, Farooqui, M M, Grigore, L, Kraft, M, Hollinshead, N. Electroplating moulds using dry film thick negative photoresist. Journal of micromechanics and microengineering.: structures, devices, and systems, vol.13, no.4, S67-S74.
Zhang, Jun, Chan-Park, Mary B., Conner, Samuel R.. Effect of exposure dose on the replication fidelity and profile of very high aspect ratio microchannels in SU-8. Lab on a chip, vol.4, no.6, 646-653.
Lin, Che-Hsin, Lee, Gwo-Bin, Chang, Bao-Wen, Chang, Guan-Liang. A new fabrication process for ultra-thick microfluidic microstructures utilizing SU-8 photoresist. Journal of micromechanics and microengineering.: structures, devices, and systems, vol.12, no.5, 590-597.
Proc. SPIE‐Int. Soc. Opt. Eng. LaBianca N. 846 2438 1995
Lorenz, H., Laudon, M., Renaud, P.. Mechanical characterization of a new high-aspect-ratio near UV-photoresist. Microelectronic engineering, vol.41, 371-374.
Chovelon, J. M., Aarch, L. El., Charbonnier, M., Romand, M.. Silanization of Stainless Steel Surfaces: Influence of Application Parameters. The Journal of adhesion, vol.50, no.1, 43-58.
Surface Cleaning, Finishing, and Coating Mills K. 1982
Kim, Bong Hwan, Chung, Taek Dong, Oh, Chang Hoon, Chun, Kukjin. A new organic modifier for anti-stiction. Journal of microelectromechanical systems : a joint IEEE and ASME publication on microstructures, microactuators, microsensors, and microsystems, vol.10, no.1, 33-40.
Dentinger, Paul M., Clift, W.Miles, Goods, Steven H.. Removal of SU-8 photoresist for thick film applications. Microelectronic engineering, vol.61, 993-1000.
Sens. Actuators A Phys. Shen X. ‐J. 97 2002
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.