최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Sensors and actuators. B, Chemical, v.133 no.2, 2008년, pp.533 - 537
Sun, Ke (Bio-MEMS and Microsystem Lab, Department of Electrical Engineering, University of South Florida, Tampa, FL 33620, United States) , Ramgir, Niranjan (Bio-MEMS and Microsystem Lab, Department of Electrical Engineering, University of South Florida, Tampa, FL 33620, United States) , Bhansali, Shekhar (Corresponding author.)
AbstractAn immunoelectrochemical sensor based on alkaline phosphatase (AP) enzyme for determination of salivary cortisol concentration is reported. Microfabricated Au electrodes encased in a microfluidic chamber were functionalized to immobilize the cortisol capture antibodies. The reaction product ...
J. Clin. Endocrinol. Metab. Papanicolaou 87 10 4515 2002 10.1210/jc.2002-020534 Nighttime salivary cortisol: a useful test for the diagnosis of Cushing's syndrome
Psychiatry Res. Bandelow 95 3 245 2000 10.1016/S0165-1781(00)00183-9 Diurnal variation of cortisol in panic disorder
J. Sports Sci. Rudolph 16 2 121 1998 10.1080/026404198366830 Cortisol and affective responses to exercise
Br. J. Psychiatry Roberts 184 2 136 2004 10.1192/bjp.184.2.136 Salivary cortisol response to awakening in chronic fatigue syndrome
Biol. Psychiatry Morgan 47 10 891 2000 10.1016/S0006-3223(99)00307-8 Hormone profiles in humans experiencing military survival training
Clin. Endocrinol. Antonini 52 4 423 2000 10.1046/j.1365-2265.2000.00935.x The emergence of salivary cortisol circadian rhythm and its relationship to sleep activity in preterm infants
J. Natl. Cancer Inst. Sephton 92 12 994 2000 10.1093/jnci/92.12.994 Diurnal cortisol rhythm as a predictor of breast cancer survival
E. Cullum, M.C.A. Duplessis, L.J. Crepeau, Method for the detection of stress biomarkers including cortisol by fluorescence polarization, 2006, US.
J. Chromatogr. A Jia 966 1-2 187 2002 10.1016/S0021-9673(02)00701-X Capillary electrophoretic enzyme immunoassay with electrochemical detection for cortisol
Clin. Biochem. Kushnir 37 5 357 2004 10.1016/j.clinbiochem.2004.01.005 Cortisol and cortisone analysis in serum and plasma by atmospheric pressure photoionization tandem mass spectrometry
J. Phys. Chem. C Ramgir 111 37 13981 2007 10.1021/jp073371b Voltammetric detection of cancer biomarkers exemplified by interleukin-10 and osteopontin with silica nanowires
Sens. Actuators B: Chem. Patil 129 859 2008 10.1016/j.snb.2007.09.080 Ultrasensitive electrochemical detection of cytokeratin-7, using Au nanowires based biosensor
Biosens. Bioelectron. Kumar 22 9-10 2138 2007 10.1016/j.bios.2006.09.035 Ultrasensitive detection of cortisol with enzyme fragment complementation technology using functionalized nanowire
Sens. Actuators B: Chem. Aravamudhan 127 1 29 2007 10.1016/j.snb.2007.07.008 Electrochemical biosensor for targeted detection in blood using aligned Au nanowires
J. Semiconduct. Technol. Sci. Yi 5 1 30 2005 Fabrication of electrochemical sensor with tunable electrode distance
Physiol. Behav. Dabbs 49 4 815 1991 10.1016/0031-9384(91)90323-G Salivary testosterone measurements: collecting, storing, and mailing saliva samples
Chin. Chem. Lett. Jiao 13 1 69 2002 A new voltammetric enzyme immunoassay system for the detection of alkaline phosphatase
Anal. Bioanal. Chem. Fanjul-Bolado 385 1202 2006 10.1007/s00216-006-0367-8
J. Clin. Endocrinol. Metab. Arafah 92 8 2965 2007 10.1210/jc.2007-0181 Measurement of salivary cortisol concentration in the assessment of adrenal function in critically ill subjects: a surrogate marker of the circulating free cortisol
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.