NTIS 바로가기Energy and buildings, v.43 no.11, 2011년, pp.3216 - 3225
Ng, Malcolm Owen (School of Civil Engineering, Purdue University, 550 Stadium Mall Dr., West Lafayette, IN 47906, United States) , Qu, Ming (School of Civil Engineering, Purdue University, 550 Stadium Mall Dr., West Lafayette, IN 47906, United States) , Zheng, Pengxuan (Department of Computer Science, Purdue University, 305 N. University St., West Lafayette, IN 47907, United States) , Li, Zhiyuan (Department of Computer Science, Purdue University, 305 N. University St., West Lafayette, IN 47907, United States) , Hang, Yin (School of Civil Engineering, Purdue University, 550 Stadium Mall Dr., West Lafayette, IN 47906, United States)
Highlights► CO2-based occupancy detection scheme provides good agreement to actual occupancy, with χ2 of 0.2063. ► CO2-based DCV under ASHRAE 62 leads to substantially lower ventilation rates than ASHRAE 62.1. ► IAQ is preserved by both standards. ► Proportional c...
ASHRAE Transactions Kusuda 82 1169 1976 Control of ventilation to conserve energy while maintaining acceptable indoor air quality
Turiel 1979 Variable Ventilation Control Systems: Saving Energy and Maintaining Indoor Air Quality
Emmerich 2001 State-of-the-Art Review of CO2 Demand Controlled Ventilation Technology and Application, NISTIR 6729
Building and Environment Sun 46 124 2011 10.1016/j.buildenv.2010.07.008 In-situ implementation and validation of a CO2-based adaptive demand-controlled ventilation strategy in a multi-zone office building
Energy and Buildings Nielsen 42 1995 2010 10.1016/j.enbuild.2010.06.006 Energy efficient demand controlled ventilation in single family houses
Energy and Buildings Wachenfeldt 39 1073 2007 10.1016/j.enbuild.2006.10.018 Air flow rates and energy saving potential in schools with demand-controlled displacement ventilation
Building and Environment Chao 39 4 385 2004 10.1016/j.buildenv.2003.11.001 Development of a dual-mode demand control ventilation strategy for indoor air quality control and energy saving
Energy and Buildings Yang 43 414 2011 10.1016/j.enbuild.2010.10.004 Evaluation of four control strategies for building VAV air-conditioning systems
Simulation Modelling Practice and Theory Jeong 18 51 2010 10.1016/j.simpat.2009.09.009 Improvement in demand-controlled ventilation simulation on multi-purposed facilities under an occupant based ventilation standard
Applied Thermal Engineering Xu 29 91 2009 10.1016/j.applthermaleng.2008.02.017 A model-based optimal ventilation control strategy of multi-zone VAV air-conditioning systems
ASHRAE Transactions Lawrence 113 1 227 2004 Calibrated simulation for retrofit evaluation of demand-controlled ventilation in small commercial buildings
Energy and Buildings Mysen 37 1234 2005 10.1016/j.enbuild.2005.01.003 Occupancy density and benefits of demand-controlled ventilation in Norwegian primary schools
Energy and Buildings Pavlovas 36 1029 2004 10.1016/j.enbuild.2004.06.009 Demand controlled ventilation: a case study for the existing Swedish multifamily buildings
Norwegian Health Department, Forskrift om milijorettet helsevern I skoler og barnehager (Regulations for Environmental Health Protection in Schools and Day-Care Centers), Norway, 2003 (in Norwegian).
Building Regulations 2008, The Danish Ministry of Economic and Business Affairs, Danish Enterprise and Construction Authority, Copenhagen, Denmark, 2007.
KICT 2006 A Guide for Ventilation System Installation to Reduce Sick Building Syndrome in Apartment Houses and Multi-purposed Facilities
ASHRAE 1989 ANSI/ASHRAE Standard 62-1989, Ventilation for Acceptable Indoor Air Quality
ASHRAE Journal Schell 43 2 18 2001 Demand control ventilation using CO2
ASHRAE 2007 Standard 62.1-2007 User's Manual
HPAC Engineering Murphy 80 36 2008 CO2-based demand-controlled ventilation with ASHRAE Standard 62.1
Indoor Air Wargocki 10 4 222 2000 10.1034/j.1600-0668.2000.010004222.x The effects of outdoor air supply rate in an office on perceived air quality, sick building syndrome, symptoms and productivity
Indoor Air Suess 2 180 1992 10.1111/j.1600-0668.1992.06-23.x The indoor air quality programme of the WHO regional office for Europe
Indoor Air Norback 5 4 237 1995 10.1111/j.1600-0668.1995.00003.x Subjective indoor air quality in schools - the influence of high room temperature, carpeting, fleecy wall materials and volatile organic compounds (VOC)
Indoor Air Daisey 13 1 53 2003 10.1034/j.1600-0668.2003.00153.x Indoor air quality ventilation and health symptoms in schools: an analysis of existing information
Indoor Air Godwin 17 2 109 2007 10.1111/j.1600-0668.2006.00459.x Indoor air quality in Michigan schools
Indoor Air Sundell 14 7 51 2004 10.1111/j.1600-0668.2004.00273.x On the history of indoor air quality and health
Indoor Air Fanger 5 328 2006 10.1111/j.1600-0668.2006.00437.x What is IAQ?
CEC, Guidelines for Ventilation Requirements in Buildings, Report No. 11, European Concerted Action Indoor Air Quality & its Impact on Man, Commission of the European Communities, Brussels, 1992.
ASHRAE 2009 2009 ASHRAE Handbook - Fundamentals, I-P ed.
Indoor and Built Environment Wang 7 165 1998 10.1159/000024577 CO2-based occupancy detection for on-line outdoor air flow control
Indoor and Built Environment Wang 8 377 1999 10.1177/1420326X9900800605 Experimental validation of CO2-based occupancy detection for demand-controlled ventilation
ASHRAE Journal Taylor 48 5 67 2006 Demand-controlled ventilation: CO2-based DCV using 62.1-2004
ASHRAE 2010 ANSI/ASHRAE Standard 62.1-2010, Ventilation for Acceptable Indoor Air Quality
ASHRAE 2007 62.1 User's Manual, ANSI/ASHRAE Standard 62.1-2007, Ventilation for Acceptable Indoor Air Quality
Satish 2011 Indoor Air Conference Impact of CO2 on human decision making and productivity
F-chart Software, Engineering Equation Solver - EES Professional, Madison, WI 53744, USA, 2007.
Norberg 2011 Indoor Air Conference CO2 measurements - an indicator of hidden microbial damages in buildings
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.