최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Water research, v.49, 2014년, pp.62 - 82
Jouanneau, S. , Recoules, L. , Durand, M.J. , Boukabache, A. , Picot, V. , Primault, Y. , Lakel, A. , Sengelin, M. , Barillon, B. , Thouand, G.
The Biochemical Oxygen Demand (BOD) is one of the most widely used criteria for water quality assessment. It provides information about the ready biodegradable fraction of the organic load in water. However, this analytical method is time-consuming (generally 5 days, BOD5), and the results may vary ...
Enzyme Microb. Technol. Arlyapov 50 4-5 215 2012 10.1016/j.enzmictec.2012.01.002 Biosensor analyzer for BOD index express control on the basis of the yeast microorganisms Candida maltosa, Candida blankii, and Debaryomyces hansenii
Rev. Environ. Sci. Bio/Technol. Arora 9 3 211 2010 10.1007/s11157-010-9211-x Tools of bioinformatics in biodegradation
Molecules (Basel, Switzerland) Baker 9 12 989 2004 10.3390/91200989 Evaluation of artificial intelligence based models for chemical biodegradability prediction
Environ. Monit. Assess. Bari 5 4 423 1985 10.1007/BF00399469 Measurement of wastewater treatment efficiency by fluorescence and UV absorbance
Appl. Microbiol. Biotechnol. Baronian 60 1 108 2002 Detection of two distinct substrate-dependent catabolic responses in yeast cells using a mediated electrochemical method
Ozone: Sci. Eng. Beltran 19 6 495 1997 10.1080/01919512.1997.10382876 Impact of chemical oxidation on biological treatment of a primary municipal wastewater. 1. Effects on cod and biodegradability
Biotechnol. Bioeng. Bennetto 25 2 559 1983 10.1002/bit.260250219 Anodic reactions in microbial fuel cells
Ecotoxicol. Environ. Saf. Blok 8 5 410 1984 10.1016/0147-6513(84)90063-0 Biodegradability test results related to quality and quantity of the inoculum
Sewage Works J. Caldwell 20 2 202 1948 Manometric measurement of the biochemical oxygen demand of sewage
Limnol. Oceanogr. Carpenter 10 1 135 1965 10.4319/lo.1965.10.1.0135 The accuracy of the Winkler method for dissolved oxygen analysis
Talanta Catterall 55 6 1187 2001 10.1016/S0039-9140(01)00527-6 The use of microorganisms with broad range substrate utilisation for the ferricyanide-mediated rapid determination of biochemical oxygen demand
Anal. Chem. Catterall 75 11 2584 2003 10.1021/ac0206420 Development of a rapid ferricyanide-mediated assay for biochemical oxygen demand using a mixed microbial consortium
Biosens. Bioelectron. Chan 14 2 131 1999 10.1016/S0956-5663(98)00110-9 Measurement of biodegradable substances using the salt-tolerant yeast Arxula adeninivorans for a microbial sensor immobilized with poly(carbamoyl) sulfonate (PCS) part I: construction and characterization of the microbial sensor
Biosens. Bioelectron. Chan 15 7-8 343 2000 10.1016/S0956-5663(00)00090-7 Designing an amperometric thick-film microbial BOD sensor
Biosens. Bioelectron. Chang 19 6 607 2004 10.1016/S0956-5663(03)00272-0 Continuous determination of biochemical oxygen demand using microbial fuel cell type biosensor
Biosens. Bioelectron. Chang 20 9 1856 2005 10.1016/j.bios.2004.06.003 Improvement of a microbial fuel cell performance as a BOD sensor using respiratory inhibitors
Anal. Chim. Acta Chee 394 1 65 1999 10.1016/S0003-2670(99)00289-5 Development of highly sensitive BOD sensor and its evaluation using preozonation
Anal. Chim. Acta Chee 379 1-2 185 1999 10.1016/S0003-2670(98)00680-1 Biosensor for the estimation of low biochemical oxygen demand
Sens. Actuators B: Chem. Chee 80 1 15 2001 10.1016/S0925-4005(01)00883-8 Biosensor for the evaluation of biochemical oxygen demand using photocatalytic pretreatment
Biosens. Bioelectron. Chee 21 1 67 2005 10.1016/j.bios.2004.10.005 Development of photocatalytic biosensor for the evaluation of biochemical oxygen demand
Anal. Bioanal. Chem. Chen 372 5 737 2002 10.1007/s00216-001-1214-6 A BOD biosensor based on a microorganism immobilized on an Al2O3 sol-gel matrix
J. Chem. Inf. Model. Cheng 52 3 655 2012 10.1021/ci200622d In silico assessment of chemical biodegradability
Sens. Actuators B: Chem. Chiappini 148 1 103 2010 10.1016/j.snb.2010.04.039 A new microbial biosensor for organic water pollution based on measurement of carbon dioxide production
Constant 2009 Rapid Chemical and Biological Techniques for Water Monitoring UV spectrophotometry: environmental monitoring solutions
Czekanska 2011 Mammalian Cell Viability, Methods in Molecular Biology Assessment of cell proliferation with resazurin-based fluorescent dye
Int. J. Environ. Anal. Chem. Dai 84 8 607 2004 10.1080/03067310310001658302 Comparison of BOD optical fiber biosensors based on different microorganisms immobilized in ormosil matrixes
J. Chem. Technol. Biotechnol. Delaney 34 1 13 1984 10.1002/jctb.280340104 Electron-transfer coupling in microbial fuel cells. 2. Performance of fuel cells containing selected microorganism-mediator-substrate combinations
Water Res. Di Lorenzo 43 13 3145 2009 10.1016/j.watres.2009.01.005 A single-chamber microbial fuel cell as a biosensor for wastewaters
Water Res. Dobbs 6 10 1173 1972 10.1016/0043-1354(72)90017-6 The use of ultra-violet absorbance for monitoring the total organic carbon content of water and wastewater
Anal. Bioanal. Chem. Dudal 384 1 175 2006 10.1007/s00216-005-0140-4 A fluorescence-based microplate assay to quantify DOM-induced catabolic activity
Water Res. Edwards 21 1 49 1987 10.1016/0043-1354(87)90098-4 Relationships between ultraviolet absorbance and total organic carbon in two upland catchments
Geating 1981 Literature Study of the Biodegradability of Chemicals in Water
Great Britain 1908 Royal Commission on Sewage Disposal
Separat. Purif. Technol. Grzebyk 41 3 321 2005 10.1016/j.seppur.2004.04.009 Microbial fuel cells (MFCs) with interpolymer cation exchange membranes
Guyard vol. 334 2010
Sensors (Basel, Switzerland) Hur 12 1 972 2012 10.3390/s120100972 Prediction of BOD, COD, and total Nitrogen concentrations in a typical urban river using a fluorescence excitation-emission matrix with PARAFAC and UV absorption indices
Sensors (Basel, Switzerland) Hur 10 4 2460 2010 10.3390/s100402460 Estimation of biological oxygen demand and chemical oxygen demand for combined sewer systems using synchronous fluorescence spectra
ISO 5813:1983 Water Quality - Determination of Dissolved Oxygen - Iodometric Method, n.d.
ISO 5814:1990 Water Quality - Determination of Dissolved Oxygen - Electrochemical Probe Method, n.d.
ISO 5815-1:2003 2003 Water Quality - Determination of Biochemical Oxygen Demand after N Days (BODn) - Part 1: Dilution and Seeding Method with Allylthiourea Addition
ISO 5815-2:2003 2003 Water Quality - Determination of Biochemical Oxygen Demand after N Days (BODn) - Part 2: Method for Undiluted Samples
Process Biochem. Jang 39 8 1007 2004 10.1016/S0032-9592(03)00203-6 Construction and operation of a novel mediator- and membrane-less microbial fuel cell
Biosens. Bioelectron. Jia 18 8 1023 2003 10.1016/S0956-5663(02)00225-7 Co-immobilized microbial biosensor for BOD estimation based on sol-gel derived composite material
Talanta Jiang 70 1 97 2006 10.1016/j.talanta.2005.11.046 Optical biosensor for the determination of BOD in seawater
Environ. Sci. Technol. Jouanneau 46 21 11979 2012 10.1021/es3024918 Online detection of metals in environmental samples: comparing two concepts of bioluminescent bacterial biosensors
Electroanalysis Kalab 6 11-12 1004 1994 10.1002/elan.1140061114 Evaluation of mediators for development of amperometric microbial bioelectrodes
Biotechnol. Bioeng. Karube 19 10 1535 1977 10.1002/bit.260191010 Microbial electrode BOD sensors
Sens. Actuators B: Chem. Kim 80 1 9 2001 10.1016/S0925-4005(01)00879-6 Klebsiella BOD sensor
Sens. Actuators B: Chem. Kim 98 1 1 2004 10.1016/j.snb.2003.07.001 Immobilization of enzymes for Klebsiella BOD sensor
Biotechnol. Lett. Kim 25 7 541 2003 10.1023/A:1022891231369 Novel BOD (biological oxygen demand) sensor using mediator-less microbial fuel cell
Limnol. Oceanogr. Klimant 40 6 1159 1995 10.4319/lo.1995.40.6.1159 Fiber-optic oxygen microsensors, a new tool in aquatic biology
Appl. Environ. Microbiol. Koster 72 11 7063 2006 10.1128/AEM.00641-06 Microbiosensors for measurement of microbially available dissolved organic carbon: sensor characteristics and preliminary environmental application
Biosens. Bioelectron. Kumlanghan 22 12 2939 2007 10.1016/j.bios.2006.12.014 Microbial fuel cell-based biosensor for fast analysis of biodegradable organic matter
Enzyme Microb. Technol. Kumlanghan 42 6 483 2008 10.1016/j.enzmictec.2008.01.012 Microbial BOD sensor for monitoring treatment of wastewater from a rubber latex industry
Sens. Actuators B: Chem. Kwok 110 2 289 2005 10.1016/j.snb.2005.02.007 An optical biosensor for multi-sample determination of biochemical oxygen demand (BOD)
Sensors (Basel, Switzerland) Lai 11 8 7382 2011 10.3390/s110807382 Estimating the biodegradability of treated sewage samples using synchronous fluorescence spectra
J. Appl. Microbiol. Learoyd 72 6 479 1992 An investigation of dye reduction by food-borne bacteria
Biosens. Bioelectron. Lehmann 14 3 295 1999 10.1016/S0956-5663(98)00128-6 Measurement of biodegradable substances using the salt-tolerant yeast Arxula adeninivorans for a microbial sensor immobilized with poly(carbamoyl)sulfonate (PCS): Part II: application of the novel biosensor to real samples from coastal and island regions
Appl. Biochem. Biotechnol. Li 28-29 1 855 1991 10.1007/BF02922655 Study of BOD microbial sensors for waste water treatment control
Biosens. Bioelectron. Lin 21 9 1703 2006 10.1016/j.bios.2005.08.007 Novel BOD optical fiber biosensor based on co-immobilized microorganisms in ormosils matrix
Biosens. Bioelectron. Liu 14 12 883 2000 10.1016/S0956-5663(99)00064-0 Immobilised activated sludge based biosensor for biochemical oxygen demand measurement
Biosens. Bioelectron. Liu 20 3 562 2004 10.1016/j.bios.2004.03.008 Short-term BOD (BODst) as a parameter for on-line monitoring of biological treatment process: Part I. A novel design of BOD biosensor for easy renewal of bio-receptor
Biosens. Bioelectron. Liu 20 3 571 2004 10.1016/j.bios.2004.03.007 Short-term BOD (BODst) as a parameter for on-line monitoring of biological treatment process: Part II: instrumentation of integrated flow injection analysis (FIA) system for BODst estimation
Biosens. Bioelectron. Liu 25 2 523 2009 10.1016/j.bios.2009.08.004 Organic-inorganic hybrid material for the cells immobilization: long-term viability mechanism and application in BOD sensors
Biosens. Bioelectron. Liu 26 5 2074 2011 10.1016/j.bios.2010.09.004 Immobilized multi-species based biosensor for rapid biochemical oxygen demand measurement
Biosens. Bioelectron. Liu 34 1 77 2012 10.1016/j.bios.2012.01.020 A biofilm reactor-based approach for rapid on-line determination of biodegradable organic pollutants
Sens. Actuators B: Chem. McDonagh 74 1-3 124 2001 10.1016/S0925-4005(00)00721-8 Phase fluorometric dissolved oxygen sensor
Analyst McEvoy 121 6 785 1996 10.1039/AN9962100785 Dissolved oxygen sensor based on fluorescence quenching of oxygen-sensitive ruthenium complexes immobilized in sol-gel-derived porous silica coatings
FASEB J. Meighen 7 11 1016 1993 10.1096/fasebj.7.11.8370470 Bacterial bioluminescence: organization, regulation, and application of the lux genes
Water Res. Mrkva 9 5-6 587 1975 10.1016/0043-1354(75)90086-X Automatic u.v.-control system for relative evaluation of organic water pollution
Water Res. Mrkva 17 2 231 1983 10.1016/0043-1354(83)90104-5 Evaluation of correlations between absorbance at 254 nm and COD of river waters
Pure Appl. Chem. Nagel 64 1 143 1992 10.1351/pac199264010143 Glossary for chemists of terms used in biotechnology (IUPAC recommendations 1992)
Anal. Chim. Acta Nakamura 602 1 94 2007 10.1016/j.aca.2007.08.050 A chemiluminescence biochemical oxygen demand measuring method
Anal. Biochem. Nakamura 369 2 168 2007 10.1016/j.ab.2007.06.040 A spectrophotometric biochemical oxygen demand determination method using 2,6-dichlorophenolindophenol as the redox color indicator and the eukaryote Saccharomyces cerevisiae
Talanta Nakamura 72 1 210 2007 10.1016/j.talanta.2006.10.019 A new BOD estimation method employing a double-mediator system by ferricyanide and menadione using the eukaryote Saccharomyces cerevisiae
Water Res. Okey 30 9 2206 1996 10.1016/0043-1354(96)00098-X A QSAR-based biodegradability model-A QSBR
Biosens. Bioelectron. Oota 26 1 262 2010 10.1016/j.bios.2010.06.040 Development of mediated BOD biosensor system of flow injection mode for Shochu distillery wastewater
Chemosphere Pagga 35 12 2953 1997 10.1016/S0045-6535(97)00262-2 Testing biodegradability with standardized methods
Appl. Microbiol. Biotechnol. Pasco 53 5 613 2000 10.1007/s002530051666 Biochemical mediator demand - a novel rapid alternative for measuring biochemical oxygen demand
Biosens. Bioelectron. Pasco 20 3 524 2004 10.1016/j.bios.2004.02.016 MICREDOX®-development of a ferricyanide-mediated rapid biochemical oxygen demand method using an immobilised Proteus vulgaris biocomponent
Anal. Chem. Preininger 66 11 1841 1994 10.1021/ac00083a011 Optical fiber sensor for biological oxygen demand
Water Res. Qian 32 3 801 1998 10.1016/S0043-1354(97)00278-9 Response characteristics of a dead-cell bod sensor
Water Res. Qian 33 13 2923 1999 10.1016/S0043-1354(99)00011-1 BOD measurement in the presence of heavy metal ions using a thermally-killed-Bacillus subtilis biosensor
Trends Biotechnol. Rabaey 23 6 291 2005 10.1016/j.tibtech.2005.04.008 Microbial fuel cells: novel biotechnology for energy generation
Anal. Chim. Acta Ramsay 215 0 61 1988 10.1016/S0003-2670(00)85266-6 Development of an electrochemical method for the rapid determination of microbial concentration and evidence for the reaction mechanism
Biosens. Bioelectron. Rastogi 18 1 23 2003 10.1016/S0956-5663(02)00108-2 Development and characterization of a novel immobilized microbial membrane for rapid determination of biochemical oxygen demand load in industrial waste-waters
Curr. Appl. Phys. Rastogi 3 2-3 191 2003 10.1016/S1567-1739(02)00199-2 BOD analysis of industrial effluents: 5 days to 5 min
Water Res. Raud 47 7 2555 2013 10.1016/j.watres.2013.02.026 Bioelectronic tongue and multivariate analysis: a next step in BOD measurements
Enzyme Microb. Technol. Raud 50 4-5 221 2012 10.1016/j.enzmictec.2012.01.003 Comparative study of semi-specific Aeromonas hydrophila and universal Pseudomonas fluorescens biosensors for BOD measurements in meat industry wastewaters
J. Hazard. Mater. Raymond 84 2-3 189 2001 10.1016/S0304-3894(01)00207-2 A review of structure-based biodegradation estimation methods
Biosens. Bioelectron. Reiss 13 10 1083 1998 10.1016/S0956-5663(98)00071-2 Determination of BOD-values of starch-containing waste water by a BOD-biosensor
Water Res. Reuschenbach 37 7 1571 2003 10.1016/S0043-1354(02)00528-6 A critical comparison of respirometric biodegradation tests based on OECD 301 and related test methods
Water Res. Reynolds 31 8 2012 1997 10.1016/S0043-1354(97)00015-8 Rapid and direct determination of wastewater BOD values using a fluorescence technique
Riedel 2002 Microbial Sensors on a Respiratory Basis for Wastewater Monitoring
Eau Ind. Nuisances Rocher 346 143 2011 New tools for the determination of PO43? and BOD in municipal wastewaters
J. Chem. Technol. Biotechnol. Roller 34 1 3 1984 10.1002/jctb.280340103 Electron-transfer coupling in microbial fuel cells: 1. Comparison of redox-mediator reduction rates and respiratory rates of bacteria
Biosens. Bioelectron. Sakaguchi 19 2 115 2003 10.1016/S0956-5663(03)00170-2 A rapid BOD sensing system using luminescent recombinants of Escherichia coli
Biosens. Bioelectron. Sakaguchi 22 7 1345 2007 10.1016/j.bios.2006.06.008 Rapid and onsite BOD sensing system using luminous bacterial cells-immobilized chip
Appl. Microbiol. Biotechnol. Suriyawattanakul 59 1 40 2002 10.1007/s00253-002-0980-1 The use of co-immobilization of Trichosporon cutaneum and Bacillus licheniformis for a BOD sensor
Swisher 1987 Surfactant Biodegradation
Sens. Actuators B: Chem. Tan 107 2 546 2005 10.1016/j.snb.2004.11.013 Thermally killed cells of complex microbial culture for biosensor measurement of BOD of wastewater
Sens. Actuators B: Chem. Tan 40 1 65 1997 10.1016/S0925-4005(97)00013-0 Dead Bacillus subtilis cells for sensing biochemical oxygen demand of waters and wastewaters
Ecotoxicol. Environ. Saf. Thouand 30 3 274 1995 10.1006/eesa.1995.1031 Bacterial inoculum density and probability of para-nitrophenol biodegradability test response
Ecotoxicol. Environ. Saf. Thouand 33 3 261 1996 10.1006/eesa.1996.0033 Preadapted inocula for limiting the risk of errors in biodegradability tests
Electrochemistry Commun. Timur 9 7 1810 2007 10.1016/j.elecom.2007.04.012 Development of a microbial biosensor based on carbon nanotube (CNT) modified electrodes
Biosens. Bioelectron. Tizzard 22 5 759 2006 10.1016/j.bios.2006.01.011 A resazurin-based biosensor for organic pollutants
Biochem. Eng. J. Torrents 66 0 27 2012 10.1016/j.bej.2012.04.014 Design of a microfluidic respirometer for semi-continuous amperometric short time biochemical oxygen demand (BODst) analysis
Appl. Microbiol. Biotechnol. Trosok 56 3 550 2001 10.1007/s002530100674 Mediated microbial biosensor using a novel yeast strain for wastewater BOD measurement
J. Water Pollut. Control Fed. Vernimmen 39 6 1006 1967 A short-term biochemical oxygen demand test
Bioproc. Biosyst. Eng. Villalobos 33 8 961 2010 10.1007/s00449-010-0420-z A BOD monitoring disposable reactor with alginate-entrapped bacteria
Biosens. Bioelectron. Wang 25 7 1705 2010 10.1016/j.bios.2009.12.018 An innovative reactor-type biosensor for BOD rapid measurement
Arch. Microbiol. Watanabe 145 4 342 1986 10.1007/BF00470868 Expression of luminescence in Photobacterium phosphoreum Na+ regulation of in vivo luminescence appearance
Meas. Sci. Technol. Xin 18 9 2878 2007 10.1088/0957-0233/18/9/017 An optical biosensing film for biochemical oxygen demand determination in seawater with an automatic flow sampling system
Sens. Actuators. B Chem. Xiong 117 1 172 2006 10.1016/j.snb.2005.11.044 Dissolved oxygen sensor based on fluorescence quenching of oxygen-sensitive ruthenium complex immobilized on silica-Ni-P composite coating
Anal. Chem. Xu 66 23 4133 1994 10.1021/ac00095a004 Oxygen sensors based on luminescence quenching: interactions of metal complexes with the polymer supports
Appl. Microbiol. Biotechnol. Yang 46 1 10 1996 10.1007/s002530050776 Disposable sensor for biochemical oxygen demand
J. Ferment. Bioeng. Yashiki 82 3 319 1996 10.1016/0922-338X(96)88828-3 Extracellular reduction of menadione and ferricyanide in yeast cell suspension
The Analyst Yoshida 125 12 2280 2000 10.1039/b005995l A mediator-type biosensor as a new approach to biochemical oxygen demand estimation
J. Biotechnol. Yoshida 88 3 269 2001 10.1016/S0168-1656(01)00282-6 Improvement of a mediator-type biochemical oxygen demand sensor for on-site measurement
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.