최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기Mechanical systems and signal processing, v.116, 2019년, pp.816 - 831
Furtmüller, Thomas (Unit of Applied Mechanics, University of Innsbruck) , Di Matteo, Alberto (Dipartimento di Ingegneria Civile, Ambientale, Aerospaziale, dei Materiali (DICAM), Università) , Adam, Christoph (degli Studi di Palermo) , Pirrotta, Antonina (Unit of Applied Mechanics, University of Innsbruck)
Abstract In this study, a novel passive vibration control strategy is investigated experimentally, where a Tuned Liquid Column Damper protects a base-isolated structure. The Tuned Liquid Column Damper is attached to the base, in contrast to typical attachment points of passive energy dissipation de...
J. Vib. Control Saaed 21 5 919 2015 10.1177/1077546313478294 A state-of-the-art review of structural control systems
Earthquake Spectra Kelly 6 2 223 1990 10.1193/1.1585566 Base isolation: linear theory and design
M.C. Constantinou, T.T. Soong, G.F. Dargush, Passive energy dissipation systems for structural design and retrofit, Report MCEER-98-MN01, Multidisciplinary Center for Earthquake Engineering Research, 1998.
Mech. Syst. Signal Process. Altunisik 102 59 2018 10.1016/j.ymssp.2017.09.021 Experimental study on control performance of tuned liquid column dampers considering different excitation directions
J. Acoust. Vibr. Ziegler 12 25 2007 The tuned liquid column damper as a cost-effective alternative for the mechanical damper in civil engineering structures
Struct. Control Health Monit. Hochrainer 13 6 980 2006 10.1002/stc.90 Control of tall building vibrations by sealed tuned liquid column dampers
Int. J. Solids Struct. Tsai 32 8 1195 1995 10.1016/0020-7683(94)00150-U The effect of tuned-mass dampers on the seismic response of base-isolated structures
J. Eng. Mech. Yang 117 4 836 1991 10.1061/(ASCE)0733-9399(1991)117:4(836) Aseismic hybrid control systems for building structures
ISET J. Earthquake Technol. Palazzo 36 121 1999 Combined control strategies: base isolation and tuned mass damping
Eng. Struct. Taniguchi 30 12 3478 2008 10.1016/j.engstruct.2008.05.027 Effect of tuned mass damper on displacement demand of base-isolated structures
Struct. Control Health Monit. Xiang 21 1 98 2014 10.1002/stc.1556 Optimum design for more effective tuned mass damper system and its application to base-isolated buildings
Arch. Appl. Mech. Khalid 82 10 1423 2012 10.1007/s00419-012-0667-8 A novel aseismic foundation system for multipurpose asymmetric buildings
10.1007/s00707-017-1980-7 A. Di Matteo, T. Furtmuller, C. Adam, A. Pirrotta, The effect of tuned liquid column dampers on the seismic response of base-isolated structures, Acta Mech.https://doi.org/10.1007/s00707-017-1980-7.
C. Adam, A. Hruska, M. Kofler, Elastic structures with tuned liquid column dampers, in: Proc. XVI IMEKO (International Measurement Confederation) World Congress, vol. VII, 2000, pp. 351-356.
Eng. Struct. Di Matteo 75 528 2014 10.1016/j.engstruct.2014.05.045 Experimental validation of a direct pre-design formula for TLCD
Meccanica Di Matteo 50 795 2015 10.1007/s11012-014-0051-6 Optimal tuning of tuned liquid column damper systems in random vibration by means of an approximate formulation
Int. J. Non-Linear Mech. Di Matteo 63 19 2014 10.1016/j.ijnonlinmec.2014.03.009 Direct evaluation of the equivalent linear damping for TLCD systems in random vibration for pre-design purposes
Commun. Nonlinear Sci. Numer. Simul. Di Matteo 23 229 2015 10.1016/j.cnsns.2014.11.005 Innovative modeling of tuned liquid column damper motion
Smart Struct. Syst. Di Matteo 18 1 117 2016 10.12989/sss.2016.18.1.117 Innovative modeling of tuned liquid column damper controlled structures
Acta Mech. Ruiz 237 3275 2016 10.1007/s00707-015-1536-7 Modeling and experimental validation of a new type of tuned liquid damper
Earthquakes Struct. Takewaki 5 4 461 2013 10.12989/eas.2013.5.4.461 New experimental system for base-isolated structures with various dampers and limit aspect ratio
L. Petti, G. Giannattasio, M. De Iuliis, B. Palazzo, Small scale experimental testing to verify the effectiveness of the base isolation and tuned mass dampers combined control strategy, in: The 14th World Conference on Earthquake Engineering, Beijing, China, 2008.
Brandt 2011 Noise and Vibration Analysis
Hochrainer 2001 Control of Vibrations of Civil Engineering Structures with Special Emphasis on Tall Buildings
Ziegler 1999 Mechanics of Solids and Fluids
Roberts 1990 Random Vibration and Statistical Linearization
Chopra 2017 Dynamics of Structures
MATLAB version 9.2 (R2017a), Natick, Massachusetts: The MathWorks Inc., 2017.
IEEE Trans. Audio Electroacoust. Welch AU-15 2 70 1967 10.1109/TAU.1967.1161901 The use of Fast Fourier Transform for the estimation of power spectra: a method based on time averaging over short, modified periodograms
The MathWorks Inc, Image Processing Toolbox User’s Guide R2015b, 2015.
Ibrahim 2005 Liquid Sloshing Dynamics, Theory and Applications
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.