NTIS 바로가기비파괴검사학회지 = Journal of the Korean Society for Nondestructive Testing, v.23 no.5, 2003년, pp.409 - 417
김형근 (국방과학연구소 기술-4-4) , 이대길 (한국과학기술원 기계공학과)
Cure monitoring can be used to improve the quality and productivity of thermosetting resin matrix composite products during their manufacturing process. In this work, the sensitivity of dielectrometry was improved by adequate separation the efforts of sensor and externals on the measured signal. A n...
C. T. Herakovich, Mechanics of fibrous composites, New York, John Wiley & Sons, (1998)
C. Y. M. Tung, and P. J. Dynes, 'Relationship between viscoelestic properties and gelation in thermosetting systems', J. Appl. Polym. Sci., Vol. 27, pp. 569-574, (1982)
S. Yilmaz, W. Wirges, S. Bauer-Cogonea, S. Bauer, R. Cerhard-Multhaupt, F. Michelotti, E. Toussaere, R. Levenson, J. Liang, and J. Zvss, 'Dielectric, piezoelectric, and electro-optic monitoring of the cross-linking process and photoinduced poling of red acid magly', Appl. Phys. Lett., Vol. 70, pp. 568-570, (1997)
M. J. O. Dwyer, G. M. Maistros, S. W. James, R. P. Tatam, and I. K. Partridge, 'Relating the state of cure to the real-time internal strain development in a curing composite using in-fibre bragg gratings and dielectric sensors', Meas. Sci. Technol., Vol. 9, pp. 1153-1158, (1998)
S. Bauer-Cogonea. W. Wirges, S. Bauer, R. Gerhard-Multhaupt, J. Liang, and J. Zyss, 'Electrical determination of the degree of cross-linking in a poled non-linear optical polymer', Chem. Phys. Lett., Vol. 262, pp. 663-667, (1996)
D. R. Day, D. D. Shepard, and K. J. Craven, 'In-process end point determination of epoxy resin cure', Proc. 22nd Int. SAMPE Tech. Conf., 724-732, (1990)
J. Mijovic, J. M Kenny, A. Maffezzoli, A. Trivisano, F. Bellucci, and L. Nicolais, 'The principles of dielectric measurements for in situ monitoring of composite processing', Compos. Sci. Technol., Vol. 49, pp. 277-290, (1993)
D. R. Day, T. J. Lewis, H L. Lee, and S. D. Senturia, 'The role of boundary layer capacitance at blocking electrodes in the interpretation of dielectric cure data in adhesives', J. Adhesion, Vol. 18, pp. 73-90, (1985)
J. Mijovic, and C. F. W. Yee, 'Use of complex impedance to monitor the progress of reactions In epoxy/amine model systems', Macro-molecules, Vol. 27, pp. 7287-7293, (1994)
G. M. Maistros, and I. K. Partridge, 'Dielectric monitoring of cure in a commercial carbon-fibre composite', Compos. Sci. Technol., Vol. 53, pp. 355-359, (1995)
R. Casalini, S. Corezzi, A. Livi, G. Levita, and P. A. Rolla, 'Dielectric parameters to monitor the crosslink of epoxy resins', J. Appl. Polym. Sci., Vol. 65, pp. 17-25, (1997)
K. Nixdorf, and G. Busse, 'The dielectric properties of glass-fiber-reinforced epoxy resin during polvmerisation', Compos. Sci. Technol. Vol. 61, pp. 889-894, (2001)
G. M. Maistros, and I. K. Partridge, 'Monitoring autoclave cure in commercial carbon fibre/epoxy composites', Compos. Part B, Vol. 29B, pp. 245-250, (1998)
Y. S. Gal, W. C. Lee, O. H Kwon, N. G. Yoon, K. S. Lhim, J. K. Ahn, and K. J. Park, 'A study on the curing properties of Kevlar/ epoxy prepreg', J. Korean Society for the Composite Materials, Vol. 14, pp. 1-7, (2001)
J. S. Kim, and D. G. Lee, 'On-line cure monitoring and viscosity measurement of carbon fiber epoxy composite materials', J. Mater. Process. Tech., Vol. 37, pp. 405-416, (1993)
J. S. Kim, and D. G. Lee, 'Analysis of dielectric sensors for the cure monitoring of resin matrix composite materials', Sensor. Actuat. B-Chem., Vol. 30, pp. 159-164, (1996)
K. G. Bang, J. W. Kwon, D. G. Lee, and J. W. Lee, 'Measurement of the degree of cure of glass fiber - epoxy composites using dielectrometry', J. Mater. Process. Tech., Vol. 113, pp. 209-214, (2001)