NTIS 바로가기Journal of biomedical engineering research : the official journal of the Korean Society of Medical & Biological Engineering, v.31 no.2, 2010년, pp.123 - 128
김은주 (식품의약품안전평가원 의료제품연구부 융합기기팀) , 이민정 (식품의약품안전평가원 의료제품연구부 융합기기팀) , 이병영 (식품의약품안전평가원 의료제품연구부 융합기기팀) , 박기정 (식품의약품안전평가원 의료제품연구부 융합기기팀) , 김동섭 (식품의약품안전평가원 의료제품연구부 융합기기팀) , 이인수 (식품의약품안전청 의료기기심사부 진단기기과) , 박해대 (식품의약품안전청 의료기기심사부 진단기기과) , 정희교 (식품의약품안전청 의료기기심사부 진단기기과)
The thermometers is widely used in diagnostic medical devices, and the safety and accurate performance of these devices are important in the diagnosis and monitoring of personal health. Especially, the accuracy of infra-red thermometer is highly emphasized. Here two typical thermometers are utilized...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
World Medical Association(WMA) statement on reducing the Global Burden of Mercury, Adopted by the WMA General Assembly, Seoul, Korea, October 2008 (http://www.wma.net/en/30publications/10policies/m36/index.html)
Karlinear J, Harvie J, HCWH Global mercury Team, The global movement for mercufy-free care, Health care, Health care without harm office(HCWH), (www.noharm.org) October 15, 2007
J Mercury Thermometers, A washington toxics coalition fact sheet, 1-2, May 2002 (http://watoxics.org/files/mercury-thennometers)
Thermometers, Electronic, Infrared, Ear, ECRI. Healthcare Product Comparison System. 1-13, January 2003.
ASTM E1112 Standard Specification for Electronic Thermometer for intermittent determination of patient temperature, 2006
ASTM E1965 Standard specification of infrared thermometers of intermittent determination of patient temperature, 2003
BS EN 12470-3 Clinical thermometers: Performance of compact electrical thermometers (non-predictive and predictive) with maximum device, 2000
BS EN 12470-5 Clinical thermometers. Performance of infra-red ear thermometers (with maximum device), 2003
JIS T 4207 Infrared ear thermometers, 2005
I. Pusnik, "Development of the ISO standard for clinical thermometers", IFMBE Proceedings 16, pp. 401-404, 2007
KS P6002 Clinical electrical thermometers with maximum device, 1992 (Reapproved 2004)
Erickson, R. S., and Meyer, L. T., "Accuracy of Infrared Ear Thermometry and Other Temperature Methods in Adults", Amer. J. of Critical Care, 3, pp. 40-54, 1994
Ilsley, A. H., Rutten, A. J., and Runciman, W. B., "An Evaluation of Body Temperature Measurements," Anaesth. and Int. Care, 11, pp. 31-39, 1983.
Erickson, R. S., and Woo, T. M., "Accuracy of Infrared Ear Thermometry and Traditional Temperature Methods in Young Children", Heart & Lung, 23, pp. 181-195, 1994.
Romano, M. J., Fortenberry, J. D., Autrey, E., Hanis, S., Heyroth, T., Parmeter, P., and Stein, F., "Infrared Tympanic Thermometry in the Pediatric Intensive Care Unit," Critical Care Medicine, 21, pp. 1181-1185, 1993.
Committee Draft : IEC 62D/80601-2-56/Ed.1, Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement, 2008.
해당 논문의 주제분야에서 활용도가 높은 상위 5개 콘텐츠를 보여줍니다.
더보기 버튼을 클릭하시면 더 많은 관련자료를 살펴볼 수 있습니다.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
Free Access. 출판사/학술단체 등이 허락한 무료 공개 사이트를 통해 자유로운 이용이 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.