최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기방사선기술과학 = Journal of radiological science and technology, v.39 no.4, 2016년, pp.607 - 614
이상욱 (가톨릭대학교 인천성모병원 종양학과) , 김정구 (한서대학교 방사선학과)
The study investigates the necessity of 3 dimensional dose distribution evaluation instead of point dose and 2 dimensional dose distribution evaluation. Treatment plans were generated on the RANDO phantom to measure the precise dose distribution of the treatment site 0.5, 1, 1.5, 2, 2.5, 3 cm with t...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Mack A., Scheib S.G., Major J., et al.: Precision dosimetry for narrow photon beams used in radiosurgery Determination of Gamma Knife output factors, Medical Physics, 29(9), 2080-2089, 2002
Choi T.J., Kim O.B.: Evaluation of the output dose of a linear accelerator photon beams by using the ionization chamber TM31010 series through TG-51 protocol to postal monitoring output of RPC for 5 years, Korean Journal of Medical Physics, 22(2), 92-98, 2011
Welsh J.S., Lock M., Harari P.M., et al.: Clinical implementation of adaptive helical tomotherapy: a unique approach to image-guided intensity modulated radiotherapy, Technology in cancer research & treatment, 5(5), 465-480, 2006
Cadman P., McNutt T., Bzdusek K.: Validation of physics improvements for IMRT with a commercial treatment-planning system, Journal of Applied Clinical Medical Physics, 6(2), 74-86, 2005
Mu G., Ludlum E., Xia P.: Impact of MLC leaf position errors on simple and complex IMRT plans for head and neck cancer, Physics in medicine & biology, 53(1), 77-88, 2008
Bayouth J. E., Wendt D., Morrill S. M.: MLC quality assurance techniques for IMRT applications, Medical Physics, 30(5), 743-750, 2003
LoSasso T., Chui C. S., Ling C. C.: Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode, Medical Physics, 28(11), 2209-2219, 2001
Ju S. G., Ahn Y. C., Huh S. J., Yeo I. J.: Film dosimetry for intensity modulated radiation therapy: dosimetric evaluation, Medical Physics, 29(3), 351-355, 2002
Herzen J., Todorovic M., Cremers F., et al.: Dosimetric evaluation of a 2D pixel ionization chamber for implementation in clinical routine, Physics in medicine and biology, 52(4), 1197-1208, 2007
Daniel L, Misbah G, Di Yan, et al.: Evaluation of a 2D diode array for IMRT assurance. Radiation & Oncology, 70(1), 199-206, 2004
Young-Taek Oh, Haejin Kang, Miwha Kim et al.: Three-dimensional dosimetry using magnetic resonance imaging of polymer gel, The Journal of the Korean society for therapeutic radiology and oncology, 20(3), 264-273, 2002
Bedford J.L., Lee Y.K., Wai P., South C.P., Warrington A.P.: Evaluation of the Delta4 phantom for IMRT and VMAT verification, Physics in medicine and biology, 54(9), 167-176, 2009
Van Esch A., Clermont C., Devillers M., et al.: On-line quality assurance of rotational radiotherapy treatment delivery by means of a 2D ion chamber array and the Octavius phantom, Medical Physics, 34(10), 3825-3837, 2007
H. Fakir, S. Gaede, M. Mulligan, J.Z. Chen.: Development of a novel ArcCHECK insert for routine quality assurance of VMAT delivery including dose calculation with inhomogeneities, Medical Physics., 39(7), 4203-4208, 2012
Welsh J.S., Lock M., Harari P.M., Tome W.A., et al.: Clinical implementation of adaptive helical tomotherapy: a unique approach to image-guided intensity modulated radiotherapy, Technology in cancer research & treatment, 5(5), 465-480, 2006
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
Free Access. 출판사/학술단체 등이 허락한 무료 공개 사이트를 통해 자유로운 이용이 가능한 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.