NTIS 바로가기Nuclear engineering and technology : an international journal of the Korean Nuclear Society, v.48 no.3, 2016년, pp.799 - 804
Kim, Hyun Jin (Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology) , Kim, Hyun Nam (Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology) , Raza, Hamid Saeed (Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology) , Park, Han Beom (Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology) , Cho, Sung Oh (Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology)
A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray targ...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
L. Li, Z. Chen, Z. Zhao, D. Wu, X-ray digital intra-oral tomosynthesis for quasi-three-dimensional imaging: system, reconstruction algorithm, and experiments, Opt. Eng. 52 (2013) 013201.
K. de Faria Vasconcelos, K.M. Evangelista, C.D. Rodrigues, C. Estrela, T.O. de Sousa, M.A.G. Silva, Detection of periodontal bone loss using cone beam CT and intraoral radiography, Dentomaxillofac. Radiol. 41 (2012) 64-69.
N.S. Venkatesh Babu, P. Patel, Comparative evaluation of extraoral and intraoral periapical radiographic technique in children, Int. J. Sci. Stud. 2 (2015) 6-11.
N. Bagis, M.E. Kolsuz, S. Kursun, K. Orhan, Comparison of intraoral radiography and cone-beam computed tomography for the detection of periodontal defects: an in vitro study, BMC Oral Health 15 (2015) 64.
T. Tokuyasu, M. Yamamoto, K. Okamura, K. Yoshiura, A Training Simulator for Intraoral Radiography, 2006 IEEE/RSJ International Conference on IEEE, IEEE, New York, 2006.
I.A. Pretty, Caries detection and diagnosis: novel technologies, J. Dent. 34 (2006) 727-739.
S.H. Cho, D.Y. Kim, K.W. Baek, R.N. Lee, Introduction of Dental X-ray Imaging with New Conceptdintraoral X-ray Tube, The Magazine of the IEEK 48, 2011, p. 95.
S.H. Heo, H.J. Kim, J.M. Ha, S.O. Cho, A vacuum-sealed miniature X-ray tube based on carbon nanotube field emitters, Nanoscale Res. Lett. 7 (2012) 258.
H.J. Kim, J.M. Ha, S.H. Heo, S.O. Cho, Small-sized flat-tip CNT emitters for miniaturized X-ray tubes, J. Nano. 2012 (2012). Article ID 854602.
Y. Sakai, D. Tone, S. Nagatsu, T. Endo, S. Kita, F. Okuyama, Characterization of field emission from carbon nanofibers on a metal tip, Appl. Phys. Lett. 95 (2006) 073104.
N. De Jonge, Y. Lamy, K. Schoots, T.H. Oosterkamp, High brightness electron beam from a multi-walled carbon nanotube, Nature 420 (2002) 393-395.
G. Zhao, J. Zhang, Q. Zhang, J. Tang, O. Zhou, L.C. Qin, Fabrication and test of single nanotube emitter as point electron source, Microsc. Microanal. 10 (2004) 550-551.
G. Zhao, Q. Zhang, H. Zhang, G. Yang, O. Zhou, L.C. Qina, Field emission of electrons from a Cs-doped single carbon nanotube of known chiral indices, Appl. Phys. Lett. 89 (2006) 63113.
S.H. Heo, A. Ihsan, S.O. Cho, Transmission-type microfocus x-ray tube using carbon nanotube field emitters, Appl. Phys. Lett. 90 (2007) 183109.
R.J. Parmee, C.M. Collins, W. Milne, M.T. Cole, X-ray generation using carbon nanotubes, Nano. Convergence 2 (2015) 1-27.
E.L. Murphy, R.H. Good, Thermionic emission, field emission, and the transition region, Phys. Rev. 102 (1956) 1464.
M.J. Rivard, S.D. Davis, L.A. DeWerd, T.W. Rusch, S. Axelrod, Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent X-Ray Source: an electronic brachytherapy source, Med. Phys. 33 (2006) 4020-4022.
S.H. Heo, A. Ihsan, S.O. Cho, Stable Field Emitters for a Miniature X-ray tube using carbon nanotube drop drying on a flat metal tip, Nanoscale Res. Lett. 5 (2010) 720-724.
J.M. Ha, H.J. Kim, H.S. Raza, S.O. Cho, Highly stable carbon nanotube field emitters on small metal tips against electrical arcing, Nanoscale Res. Lett. 8 (2013) 355.
W.B. Herrmannsfeldt, G.A. Herrmannsfeldt, EGN Electron Optics Program, SLAC, Stanford, California, 1993.
Los Alamos National Lab, MCNP-A General Monte Carlo NParticle Transport, version 5, 2003.
G.J. Qiao, C.G. Zhang, Z.H. Jin, Thermal cyclic test of alumina/kovar joint brazed by Ni-Ti active filler, Ceram. Int. 29 (2003) 7-11.
G. Massillon, S. Chiu-Tsao, I. Domingo-Munoz, M. Chan, Energy dependence of the new Gafchromic EBT3 film: dose response curves for 50 kV, 6 and 15 MV X-ray beams, Int. J. Med. Phys. Clin. Eng. Radiat. Oncol. 1 (2012) 60-65.
European Committee for Standardization: EN 12543-5, E. Brussels, 1999.
※ AI-Helper는 부적절한 답변을 할 수 있습니다.