최소 단어 이상 선택하여야 합니다.
최대 10 단어까지만 선택 가능합니다.
다음과 같은 기능을 한번의 로그인으로 사용 할 수 있습니다.
NTIS 바로가기한국정보통신학회논문지 = Journal of the Korea Institute of Information and Communication Engineering, v.22 no.2, 2018년, pp.261 - 269
김송란 (Graduate School of Information and Communication Engineering, Chungbuk National University) , 정민창 (Graduate School of Information and Communication Engineering, Chungbuk National University) , 강현수 (Graduate School of Information and Communication Engineering, Chungbuk National University)
This paper presents a convenient method to estimate the internal parameters of plenoptic camera using CCD(charge-coupled device) camera model. The images used for plenoptic camera calibration generally use the checkerboard pattern used in CCD camera calibration. Based on the CCD camera model, the de...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
핵심어 | 질문 | 논문에서 추출한 답변 |
---|---|---|
플렌옵틱 영상이 활용되는 분야는? | 플렌옵틱 영상은 다양한 정보를 가지고 있기 때문에 재 초점, 3차원 모델링[2], 초고해상도 영상 생성[3] 등 다양한 분야에 활용할 수 있다. 이러한 다양한 분야에 응용하기 위해서는 정확한 파라미터를 기반으로 하여 진행되어야 한다. | |
카메라 캘리브레이션 작업이 의미하는 것은? | 3차원 공간을 카메라로 촬영하여 2차원 영상으로 변환하게 되는데 영상 획득당시의 카메라 위치나 방향, 카메라 내부의 기구적인 부분에 의해서 영향을 받는다. 따라서 정확한 계산을 위해서 카메라 내부 요인을 제거하고 내부 파라미터를 구하는 작업이 필요하다. 이러한 작업을 카메라 캘리브레이션이라고한다. | |
플렌옵틱 카메라 모델에 CCD 카메라 캘리브레이션 방법을 적용할 때 과정은? | 본 논문에서는 복잡한 플렌옵틱 카메라 캘리브레이션 방법 대신 플렌옵틱 카메라 모델에 CCD 카메라 캘리브레이션 방법을 적용하는 편리한 방법을 제안한다. 먼저 CCD 카메라 모델과 플렌옵틱 카메라 모델 사이의 수식적 관계를 도출하고 캘리브레이션을 위해 플렌옵틱 카메라 모델의 정규좌표계 행렬식을 사용한다. 이를 통해 4개의 방정식을 도출할 수 있다. 그리고 플렌옵틱 카메라를 통해 얻은 SA영상에 CCD 카메라 캘리브레이션 방법을 적용한다. 내부 파라미터는 4가지 방정식을 사용하여 비선형 최적화를 통해 유추할 수 있다. |
R. Ng, M. Levoy, M. Br' edif, G. Duval, M. Horowitz, and P. Hanrahan. "Light field photography with a hand-held plenoptic camera," Stanford University Computer Science Technical Report CSTR 2005-02, April 2005.
D. H. Kim, "SVD-based Image Enhancement Method using Weighted Average of Histogram Stretching and Equalization," Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities and Sociology, ISSN: 2383-5281, vol.5, no.5, pp. 77-85, Oct. 2015.
Z. Zhang, "A Flexible New Technique for Camera Calibration," IEEE Trans. on Pattern Analysis and Machine Intelligence, no. 22, no. 11, pp. 1330-1334, Nov. 2000.
Y. Bok, H. G. Jeon, and L. S. Kweon, "Geometric calibration of micro-lens-based light-field cameras using line features," in Proceeding of European Conference on Computer Vision, pp. 47-61, 2014.
O. Johannsen, C. Heinze, B. Goldluecke, and C. PerwaB. "On the calibration of focused plenoptic cameras," in Lecture Notes in Computer Science, vol. 8200, Springer, pp. 302-317, Sept. 2013.
C. Zhang, Z. Ji, and Q. Wang. "Decoding and calibration method on focused plenoptic camera," Computational Visual Media, vol 2, no 1, pp. 57-69, Mar. 2016.
D. G. Dansereau, O. Pizarro, and S. B. Williams. "Decoding, calibration and rectification for lenselet-based plenoptic cameras," in Proceeding of IEEE Conference on Computer Vision and Pattern Recognition, pp. 1027-1034, 2013.
S. R. Kim, H. S. Kang, S. W. Lee, "Disparity Analysis on Plenoptic Images," in Proceeding of Korea IEIE Conference, pp. 386-388, Nov. 2016.
해당 논문의 주제분야에서 활용도가 높은 상위 5개 콘텐츠를 보여줍니다.
더보기 버튼을 클릭하시면 더 많은 관련자료를 살펴볼 수 있습니다.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.
오픈액세스 학술지에 출판된 논문
※ AI-Helper는 부적절한 답변을 할 수 있습니다.