NTIS 바로가기Korean chemical engineering research = 화학공학, v.58 no.3, 2020년, pp.430 - 437
배정은 (경북대학교 응용화학공학부) , 김경훈 (경북대학교 응용화학공학부) , 추승철 (경북대학교 응용화학공학부) , 허재필 (경북대학교 응용화학공학부) , 임상훈 (경북대학교 응용화학공학부) , 성수환 (경북대학교 응용화학공학부)
In this research, the anti-windup techniques for the cascade control system are newly developed. Cascade control system has an additional internal feedback control loop to reject disturbances better than the conventional control system. Remarkable difference between the conventional single-loop cont...
* AI 자동 식별 결과로 적합하지 않은 문장이 있을 수 있으니, 이용에 유의하시기 바랍니다.
Sung, S. W., Lee, J. and Lee, I. B., Process Identification and PID Control, John Wiley & Sons (2009).
Seborg, D. E., Mellichamp, D. A., Edgar, T. F. and Doyle III, F. J., Process Dynamics and Control, John Wiley & Sons(2010).
Berner, J., Hagglund, T., and Astrom, K. J., "Asymmetric Relay Autotuning - Practical Features for Industrial Use," Control Eng. Practice, 54, 231-245(2016).
Lee, J., Sung, S. W., Lee, F. Y., Baldea, M., and Edgar, T. F., "Full Closed-Loop Tests for the Relay Feedback Autotuning of Stable, Integrating, and Unstable Processes," ACS Omega, 4(20), 18760-18770(2019).
Park, B. E., Kim, K. H., Kang, H. S., Sung, S. W. and Lee, I. B., "Improved Relay Feedback Method Under Noisy and Disturbance Environments," J. Chem. Eng. Jpn., 52(5), 430-438(2019).
Nikita, S. and Lee, M., "Control of a Wastewater Treatment Plant Using Relay Auto-tuning," Korean J. Chem. Eng., 36(4), 505-512 (2019).
Morari, M. and Zafiriou, E., Robust Process Control, Prentice Hall(1989).
Jia, B., Mikalsen, R. Smallbone, A., Zuo, Z. and Feng, H., "Piston Motion Control of a Free-piston Engine Generator: A New Approach Using Cascade Control," Appl. Energy, 179, 1166-1175 (2016).
Astrom, K. J., and Hagglund, T., PID Controllers: Theory, Design, and Tuning, Instrument Society of America(1995).
Rehan, M., Ahmed, A. and Iqbal, N., "Static and Low Order Antiwindup Synthesis for Cascade Control Systems with Actuator Saturation: An Application to Temperature-based Process Control," ISA Trans., 49(3), 293-301(2010).
Mehdi, N., Rehan, M., Malik, F. M., Bhatti, A. I. and Tufail, M., "A Novel Anti-windup Framework for Cascade Control Systems: An Application to Underactuated Mechanical Systems," ISA Trans., 53(3), 802-815(2014).
Adegbege, A. A. and Heath, W. P., "A Framework for Multivariable Algebraic Loops in Linear Anti-windup Implementations," Automatica, 83, 81-90(2017).