NTIS 바로가기한국방사선학회 논문지 = Journal of the Korean Society of Radiology, v.15 no.7, 2021년, pp.943 - 948
이영희 (동남보건대학교 간호학과) , 박재윤 (의정부 을지대학교병원 영상의학과)
The purpose of this study was to investigate changes in surface dose due to increased scattering of gamma rays from patients injected with 99mTc and 18F, which are radioactive isotopes, in close contact with materials with high atomic number such as the walls of the stable room. Prepare 99mTc and 18...
R. Fazel, H. M. Krumholz, Y. Wang, J. S Ross, J. Chen, H. H. Ting, N. D. Shah, K. N., A. J. Einstein, B. K. Nallamothu, "Exposure to Low-Dose Ionizing Radiation from Medical Imaging Procedures", New England journal of medicine, Vol. 361, No. 9, pp. 849-57, 2009. http://dx.doi.org/10.1056/NEJMoa0901249
E. C. Lin, "Radiation Risk From Medical Imaging", MAYO CLINIC PROCEEDINGS, Vol. 85, No. 12, pp. 1142-1146, 2010. http://dx.doi.org/10.4065/mcp.2010.0260
Fred A Jr Mettler, Walter Huda, Terry T Yoshizumi, Mahadevappa Mahesh, "Effective Doses in Radiology and Diagnostic Nuclear Medicine", Radiology, Vol. 248, No. 1, pp. 254-263, 2008. http://dx.doi.org/10.1148/radiol.2481071451
A. A. Mejia, T. Nakamura, I. Masatoshi, J. Hatazawa, M. Masaki, S. Watanuki, "Estimation of absorbed doses in humans due to intravenous administration of fluorine-18-fluorodeoxyglucose in PET studies", Journal of Nuclear Medicine, Vol. 32, No. 4, pp. 699-706, 1991.
F. M. Khan, J. P. Gibbons, Three-dimensional conformal radiation therapy 3rd ed, Philadelphia: Lippincott Williams & Wilkins, pp. 467-480, 2003.
P. M. Mondalek, C. G. Orton, "Transmission and build-up characteristics of polyurethane-foam immobilization devices", Treat. Plann, Vol. 7, pp. 5-10, 1982.
Joyson Kodiyan, Kyle T Amber, "Topical antioxidants in radiodermatitis: a clinical review", International journal of palliative nursing, Vol. 21, No. 9, pp. 446-498, 2015. http://dx.doi.org/10.12968/ijpn.2015.21.9.446
D. M. Shim, Y. M. Kim, S. K. Oh, Ch. M. Lim, B. T. Kown, "Radiation Induced Hand Necrosis of an Orthopaedic Surgeon Who Had Treated a Patient with Fluoroscopy-Guided Spine Injection", Journal of the Korean Orthopaedic Association, Vol. 49, No. 3, pp. 250-254, 2014. http://dx.doi.org/10.4055/jkoa.2014.49.3.250
National Research Council. "Health risks from exposure to low levels of ionizing radiation: BEIR VII phase 2", Washington, D.C.:The National Academies Press, pp.21-172, 2006.
United Nation Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), Epidemiological evaluation of radiation-induced cancer. Annex I. UNSCEAR 2000, Report Vol. II, pp. 297-450. 2000
M. K. Kalra, M. Woisetschlager, N. Dahlstrom, S. Singh, M. Lindblom, G. Choy, P. Quick, B. Schmidt, M. Sedlmair, M. A. Blake, A. Persson, "Radiation Dose Reduction With Sinogram Affirmed Iterative Reconstruction Technique for Abdominal Computed Tomography", Journal of Computer Assisted Tomography, Vol. 36, No. 3, pp. 339-346, 2012. http://dx.doi.org/10.1097/RCT.0b013e31825586c0
J. St. Germain, "The radioactive patient", Seminars In Nuclear Medicine, Vol. 16, No. 3, pp. 179-183, 1986. https://doi.org/10.1016/s0001-2998(86)80033-2
M. H. Park, J. I. Lee, "Measurement of the spatial dose rates from radioactive patients during nuclear medicine studies", Journal of the Korean Society of Radiological Technology, Vol. 25, No. 1, pp. 73-76, 2002.
S. W. Lee, S. H. Kim, B. G. Ji, et al, "A Consideration of Apron's Shielding in Nuclear Medicine Working Environment", The Korean journal of nuclear medicine technology, Vol. 18, No. 1, pp. 110-114, 2014.
Y. G. Kang, Textbook of nuclear Medicine, Chung-Ku publisher, pp. 81-86, 2013.
A. Gray, L. D. Oliver, P. N. Johnston, "The accuracy of the pencil beam convolution and anisotropic analytical algorithms in predicting the dose effects due to attenuation from immobilization devices and large air gaps", Medical physics, Vol. 36, No. 7, pp. 3181-3191, 2009. http://dx.doi.org/10.1118/1.3147204
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.