NTIS 바로가기한국지진공학회논문집 = Journal of the Earthquake Engineering Society of Korea, v.25 no.2, 2021년, pp.83 - 91
진승민 (한국전력기술(주) 토건환경기술실) , 김용복 (한국전력기술(주) 토건환경기술실) , 이용선 (한국전력기술(주) 토건환경기술실) , 문일환 (한국전력기술(주) 원자력연구실)
Seismic designs for Korean nuclear power plants (NPPs) under earthquakes' design basis are noticed due to the recent earthquake events in Korea and Japan. Japan has developed the technologies and experiences of the NPPs through theoretical research and experimental verification with extensively accu...
Japan Electric Association. Japan Elecric Association Guide 4601-2015. Technical Guidelines for Seismic Design of Nuclear Power Plants. c2015.
Japan Electric Association, Japan Electric Association Code 4601-2015. Technical Code for Seismic Design of Nuclear Power Plants. c2015.
U.S. Nuclear Regulatory Commission. Regulatory Guide 1.60. Design Response Spectra for Seismic Design of Nuclear Power Plants. c2014.
U.S. Nuclear Regulatory Commission. NUREG/CR-6728. Technical Basis for Revision of Regulatory Guidance on Design Ground Motions: Hazard-and Risk-consistent Ground Motion Spectra Guidaelines. c2001.
KEPCO E&C. Computer Program OPTIME User Manual. c2002.
Lihanand K, Tseng WS. Generation of Synthetic Time Histories Compatible with Multiple Damping Design Response Spectra. SMiRT-9. Lausanne. K2/10. c1987.
Lihanand K, Tseng WS. Development and Application of Realistic Earthquake Time Histories Compatible with Multiple Damping Design Spectra. Proc. 9th WCEE, Vol. II. c1988.
U.S. Nuclear Regulatory Commission. Standard Review Plan 3.7.1. Seismic Design Parameters. c2014.
KINS. Safety Reveiw Guidelines for Light Water Reactors 3.7.1. Seismic Design Parameters. c2014.