NTIS 바로가기International journal of precision engineering and manufacturing, v.19 no.5, 2018년, pp.737 - 744
Kim, Hyung Jin (Department of Mechanical and Mechatronics Engineering, Kangwon National University) , Seo, Young Ho (Department of Mechanical and Mechatronics Engineering, Kangwon National University) , Kim, Byeong Hee (Department of Mechanical and Mechatronics Engineering, Kangwon National University)
Deviating from existing non-contact type of intraocular pressure measurement method, which utilizes pneumatic and optical modules, this paper proposed new measurement method using pneumatic module only. In proposed method, cornea is deformed by pneumatic pressure, and pneumatic pressure reflected on...
Asrani, S., Zeimer, R., Wilensky, J., Gieser, D., Vitale, S., and Lindenmuth, K., “Large Diurnal Fluctuations in Intraocular Pressure are an Independent Risk Factor in Patients with Glaucoma,” Journal of Glaucoma, Vol. 9, No. 2, pp. 134-142, 2000.
Tonnu, P., Ho, T., Sharma, K., White, E., Bunce, C., and Garway-Heath, D., “A Comparison of Four Methods of Tonometry: Method Agreement and Interobserver Variability,” British Journal of Ophthalmology, Vol. 89, No. 7, pp. 847-850, 2005.
Gordon, M. O., Beiser, J. A., Brandt, J. D., Heuer, D. K., Higginbotham, E. J., et al., “The Ocular Hypertension Treatment Study: Baseline Factors that Predict the Onset of Primary Open-Angle Glaucoma,” Archives of ophthalmology, Vol. 120, No. 6, pp. 714-720, 2002.
Heijl, A., Leske, M. C., Bengtsson, B., Hyman, L., Bengtsson, B., and Hussein, M., “Reduction of Intraocular Pressure and Glaucoma Progression: Results from the Early Manifest Glaucoma Trial,” Archives of Ophthalmology, Vol. 120, No. 10, pp. 1268-1279, 2002.
Vernon, S. A., “Non-Contact Tonometry in the Postoperative Eye,” British Journal of Ophthalmology, Vol. 73, No. 4, pp. 247-249, 1989.
Burvenich, H., Burvenich, E., and Vincent, C., "Dynamic Contour Tonometry (DCT) Versus Non-Contact Tonometry (NCT): A Comparison Study," Bulletin De La Societ Belge D'ophtalmologie, Vol. 298, pp. 63-69, 2005.
Lee, M. and Ahn, J., "Effects of Central Corneal Stromal Thickness and Epithelial Thickness on Intraocular Pressure Using Goldmann Applanation and Non-Contact Tonometers," PLoS One, Vol. 11, No. 3, Paper No. e0151868, 2016.
Martinez-de-la-Casa, J. M., Garcia-Feijoo, J., Vico, E., Fernandez-Vidal, A., del Castillo, J. M. B., et al., “Effect of Corneal Thickness on Dynamic Contour, Rebound, and Goldmann Tonometry,” Ophthalmology, Vol. 113, No. 12, pp. 2156-2162, 2006.
Iliev, M. E., Goldblum, D., Katsoulis, K., Amstutz, C., and Frueh, B., “Comparison of Rebound Tonometry with Goldmann Applanation Tonometry and Correlation with Central Corneal Thickness,” British Journal of Ophthalmology, Vol. 90, No. 7, pp. 833-835, 2006.
Pakrou, N., Gray, T., Mills, R., Landers, J., and Craig, J., “Clinical Comparison of the Icare Tonometer and Goldmann Applanation Tonometry,” Journal of Glaucoma, Vol. 17, No. 1, pp. 43-47, 2008.
Bonomi, L., Baravelli, S., Cobbe, C., and Tomazzoli, L., “Evaluation of Keeler Pulsair Non-Contact Tonometry: Reliability and Reproducibility,” Graefe's Archive for Clinical and Experimental Ophthalmology, Vol. 229, No. 3, pp. 210-212, 1991.
Chakrabarty, L., “Goldmann Applanation Tonometry Versus Non-Contact Tonometry: A Comparative Study,” International Journal of Research in Medical Sciences, Vol. 4, No. 11, pp. 4683-4687, 2016.
Farhood, Q. K., "Comparative Evaluation of Intraocular Pressure with an Air-Puff Tonometer Versus a Goldmann Applanation Tonometer," Clinical Ophthalmology, Vol. 7, pp. 23-27, 2013.
Do Dnb, M. C. M., “180 Years of Evolution in Tonometry,” Kerala Journal of Ophthalmology, Vol. 21, No. 2, pp. 173-181, 2009.
Luce, D. A., “Determining in Vivo Biomechanical Properties of the Cornea with an Ocular Response Analyzer,” Journal of Cataract & Refractive Surgery, Vol. 31, No. 1, pp. 156-162, 2005.
Ogbuehi, K. C., “Assessment of the Accuracy and Reliability of the Topcon Ct80 Non-Contact Tonometer,” Clinical and Experimental Optometry, Vol. 89, No. 5, pp. 310-314, 2006.
Kim, H. J., "Development of Non-Contact Type Intraocular Pressure Measurement System Based on Rebounding Sound and Air-Pressure," Ph.D. Thesis, Kangwon National University, Chuncheon, 2016.
Sharif, M. A., "Heat Transfer from an Isothermally Heated Flat Surface due to Twin Oblique Slot-Jet Impingement," Procedia Engineering, Vol. 56, pp. 544-550, 2013.
Jenkins, R. C. and Hill Jr, W. G., "Investigation of VTOL Upwash Flows Formed by Two Impinging Jets," Defense Technical Information Center, Accession No. ADA047805, 1977.
Geers, L. F. G., "Multiple Impinging Jet Arrays: An Experimental Study on Flow Hand Heat Transfer," Ph.D. Thesis, Delft University of Technology, 2004.
Fuard, D., Tzvetkova-Chevolleau, T., Decossas, S., Tracqui, P., and Schiavone, P., "Optimization of Poly-Di-Methyl-Siloxane (PDMS) Substrates for Studying Cellular Adhesion and Motility," Microelectronic Engineering, Vol. 85, Nos. 5-6, pp. 1289-1293, 2008.
Pandolfi, A. and Manganiello, F., “A Model for the Human Cornea: Constitutive Formulation and Numerical Analysis,” Biomechanics and Modeling in Mechanobiology, Vol. 5, No. 4, pp. 237-246, 2006.
Dupps Jr, W. J. and Wilson, S. E., “Biomechanics and Wound Healing in the Cornea,” Experimental Eye Research, Vol. 83, No. 4, pp. 709-720, 2006.
Pandolfi, A. and Holzapfel, G. A., "Three-Dimensional Modeling and Computational Analysis of the Human Cornea Considering Distributed Collagen Fibril Orientations," Journal of Biomechanical Engineering, Vol. 130, No. 6, Paper No. 061006, 2008.
Studer, H., Larrea, X., Riedwyl, H., and Buchler, P., “Biomechanical Model of Human Cornea Based on Stromal Microstructure,” Journal of Biomechanics, Vol. 43, No. 5, pp. 836-842, 2010.
Kling, S. and Marcos, S., “Finite-Element Modeling of Intrastromal Ring Segment Implantation into a Hyperelastic Cornea,” Investigative Ophthalmology & Visual Science, Vol. 54, No. 1, pp. 881-889, 2013.
Castro, G. G., Fitt, A. D., and Sweeney, J., “On the Validity of the Imbert-Fick Law: Mathematical Modelling of Eye Pressure Measurement,” World Journal of Mechanics, Vol. 6, No. 3, pp. 35-51, 2016.
Sigal, I. A., Flanagan, J. G., and Ethier, C. R., “Factors Influencing Optic Nerve Head Biomechanics,” Investigative Ophthalmology & Visual Science, Vol. 46, No. 11, pp. 4189-4199, 2005.
Kling, S., Bekesi, N., Dorronsoro, C., Pascual, D., and Marcos, S., "Corneal Viscoelastic Properties from Finite-Element Analysis of in Vivo Air-Puff Deformation," PLoS One, Vol. 9, No. 8, Paper No. e104904, 2014.
Shimmyo, M., Ross, A. J., Moy, A., and Mostafavi, R., “Intraocular Pressure, Goldmann Applanation Tension, Corneal Thickness, and Corneal Curvature in Caucasians, Asians, Hispanics, and African Americans,” American Journal of Ophthalmology, Vol. 136, No. 4, pp. 603-613, 2003.
Elsheikh, A., Alhasso, D., and Rama, P., “Assessment of the Epithelium's Contribution to Corneal Biomechanics,” Experimental Eye Research, Vol. 86, No. 2, pp. 445-451, 2008.
Ren, R., Wang, N., Li, B., Li, L., Gao, F., et al., “Lamina Cribrosa and Peripapillary Sclera Histomorphometry in Normal and Advanced Glaucomatous Chinese Eyes with Various Axial Length,” Investigative Ophthalmology & Visual Science, Vol. 50, No. 5, pp. 2175-2184, 2009.
Ariza-Gracia, M., Zurita, J. F., Pinero, D. P., Rodriguez-Matas, J. F., and Calvo, B., "Coupled Biomechanical Response of the Cornea Assessed by Non-Contact Tonometry. A Simulation Study," PLoS One, Vol. 10, No. 3, Paper No. e0121486, 2015.
Juraeva, M., Park, B. H., Ryu, K. J., and Song, D. J., “Designing High-Speed Dental Air-Turbine Handpiece by Using a Computational Approach,” International Journal of Precision Engineering and Manufacturing, Vol. 18, No. 10, pp. 1403-1407, 2017.
Ko, D.-H., Ko, D.-C., Lim, H.-J., Lee, J.-M., and Kim, B.-M., “FESimulation Coupled with CFD Analysis for Prediction of Residual Stresses Relieved by Cryogenic Heat Treatment of Al6061 Tube,” International Journal of Precision Engineering and Manufacturing, Vol. 14, No. 8, pp. 1301-1309, 2013.
Kling, S. and Marcos, S., “Contributing Factors to Corneal Deformation in Air Puff Measurements,” Investigative Ophthalmology & Visual Science, Vol. 54, No. 7, pp. 5078-5085, 2013.
Ambrosio Jr, R., Ramos, I., Luz, A., Faria, F. C., Steinmueller, A., et al., “Dynamic Ultra High Speed Scheimpflug Imaging for Assessing Corneal Biomechanical Properties,” Revista Brasileira de Oftalmologia, Vol. 72, No. 2, pp. 99-102, 2013.
*원문 PDF 파일 및 링크정보가 존재하지 않을 경우 KISTI DDS 시스템에서 제공하는 원문복사서비스를 사용할 수 있습니다.